Skip to main content
Respiratory SafetyReviewed against current OSHA standards

Cleaning, Storing, and Inspecting Respirators: What 1910.134(h) Expects Between Uses

OSHA 1910.134(h) covers respirator cleaning, storage, inspection, and repair. What a small shop must do between uses to keep respirators in good working order.

Updated October 18, 2026
6 min read
By the WorkSafely safety team

Walk to the shelf where your shop keeps its half-mask respirators and look at them. Are they hanging off a nail near the grinder, coated in a fine film of dust? Is one sitting in the cab of a truck that has baked in the sun all summer? Is the pair that three different people share stuffed into a drawer with a box of cartridges, a tape measure, and a can of lubricant? None of these respirators may have failed a fit test or lacked a medical clearance, and the program binder may be in good order. Yet the equipment that is supposed to protect a lung is dirty, deformed, or quietly falling apart, and nobody has been asked to notice.

That gap is what paragraph (h) of OSHA's respiratory protection standard, 29 CFR 1910.134, is written for. This post answers one question: what must you do with a respirator between the moments it is on someone's face? If you are still building the broader program, our overview of OSHA's respiratory protection standard covers the written program, and the separate posts on medical evaluation and fit testing cover those paragraphs. Here we stay with maintenance and care.

The basic duty: clean, sanitary, and in good working order

Paragraph (h)(1) opens with a plain obligation. The employer must provide each respirator user with a respirator that is clean, sanitary, and in good working order. That is a result you have to achieve, and the rest of paragraph (h) describes the machinery for achieving it.

The standard says respirators must be cleaned and disinfected using the procedures in Appendix B-2 of the standard, or other procedures recommended by the respirator manufacturer, as long as those are of equivalent effectiveness. The Appendix B-2 method is not exotic. In outline, you take off the cartridges, filters, or canisters, remove parts such as speaking diaphragms and valve assemblies if the manufacturer calls for it, and throw away or repair anything defective. You wash the pieces in warm water, no hotter than 110 degrees Fahrenheit, with a mild detergent or a cleaner the manufacturer recommends, and a stiff-bristle brush is acceptable for stubborn dirt, while a wire brush is not. You rinse thoroughly, disinfect with one of the solutions the appendix describes or a commercial cleanser the manufacturer approves, rinse again, let everything dry in a clean place, then reassemble and inspect. Check your respirator's own instruction sheet first. Manufacturers sometimes specify wipes or a particular cleaner, and following them is explicitly permitted.

Disposable filtering facepieces, the familiar paper-style dust masks and N95s, are a different animal. They are not built to be washed, and trying to clean one defeats it. Treat them as single-use or follow the manufacturer's stated limits, and if one becomes soiled, damaged, or hard to breathe through, replace it.

How often: the interval depends on who uses the respirator

Many small employers assume the standard sets a weekly or monthly schedule. It does not. Paragraph (h)(1) ties the cleaning interval to how the respirator is used, and the logic is easy to follow once you see it.

A respirator issued to a single employee for that person's exclusive use must be cleaned and disinfected as often as necessary to keep it sanitary. In a dusty finishing room, that may mean after every shift. For light occasional use, it may be far less often, but the word "necessary" means you cannot simply let it slide until it smells. A respirator that is issued to more than one employee has to be cleaned and disinfected before it is worn by a different person. Respirators kept for emergency use must be cleaned and disinfected after each use, and so must respirators used for fit testing and training.

The practical consequence for a small shop is a strong reason to assign each worker a personal respirator, labeled with a name, rather than keeping a communal pool. A shared pool forces a full cleaning every time the respirator changes hands, and in a busy shop that cleaning is the step that quietly gets skipped.

Storage: protect the shape of the facepiece

Paragraph (h)(2) is about keeping a good respirator good. Respirators must be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals. They must also be stored in a way that prevents deformation of the facepiece and the exhalation valve.

Every item in that list has a real shop-floor version. The hook on the wall beside the grinder exposes the respirator to the same dust it is supposed to guard against. A truck dashboard bakes the rubber. A toolbox shares space with solvents that can attack elastomer. A respirator crushed under other equipment may seal differently than the one that was fit tested, and a facepiece that has taken a permanent set will not seal the way the fit test assumed. The usual answer is a sealable bag or a dedicated container, kept in a clean, cool, dry location, with the facepiece resting in its natural shape instead of folded or pressed.

Respirators kept for emergency use carry extra requirements. They must be kept accessible to the work area, stored in compartments or covers clearly marked as containing emergency respirators, and stored according to the manufacturer's instructions. Most small shops do not keep emergency respirators at all, since a respirator for routine use and a rescue or escape device are different categories. If you do, such as an escape-only unit placed near a hazardous process, the labeling and accessibility rules apply to it.

Inspection: before each use, and monthly for emergency units

Paragraph (h)(3) sets the inspection rhythm. Respirators used in routine situations must be inspected before each use and during cleaning. The worker who puts one on every morning is the inspector, and the inspection has a defined scope: a check of respirator function, the tightness of connections, and the condition of the facepiece, head straps, valves, connecting tube, and the cartridges, canisters, or filters. The standard also calls for a check of elastomeric parts for pliability and signs of deterioration.

In plain terms, the worker looks for a cracked or sticky facepiece, a head strap that has lost its stretch, a valve that is warped, torn, or stuck, a cartridge that is loose or past its replacement point, and any connection that does not seat firmly. That takes a minute. The skill lies in training people to do it as a habit and to know that a questionable respirator gets set aside, not worn anyway because the job is almost done.

Respirators maintained for emergency use must be inspected at least monthly, in line with the manufacturer's recommendations, and checked for proper function before and after each use. Emergency escape-only respirators are inspected before they are carried into the workplace. For emergency-use respirators, the standard also asks the employer to certify the inspection by recording the date, the name or signature of the person who made it, the findings, any required remedial action, and a serial number or other means of identifying the unit. That information can be on a tag or label attached to the storage compartment or in inspection reports kept as paper or electronic files, and it is retained until it is replaced by the next certification. Notice that this recordkeeping rule applies to emergency-use respirators. For routine respirators, the standard requires the inspection, but it does not prescribe a written log. Many shops keep a simple sign-off anyway, because an inspection no one can show was done is hard to defend.

Repairs, and the question of when to throw it away

Paragraph (h)(4) deals with respirators that fail inspection. Any respirator that fails, or is otherwise found defective, must be removed from service, and then either discarded or repaired. The repair rules are narrower than many owners expect. Repairs or adjustments may be made only by persons appropriately trained to perform them, using only the manufacturer's NIOSH-approved parts designed for that respirator, and following the manufacturer's recommendations and specifications for the type and extent of repair. Reducing and admission valves, regulators, and alarms may be adjusted or repaired only by the manufacturer or a technician the manufacturer has trained.

For a small shop using ordinary half-mask respirators, the sensible reading is that replacing a worn valve or head strap with the genuine part from the same manufacturer may be reasonable, while taping a crack, borrowing a cartridge from a different brand, or improvising a replacement strap is not. A cheap respirator with a damaged facepiece is almost always better replaced than repaired, and if it is replaced, the new model may need its own fit test, since a different size or model is a different seal.

Making it routine without building a bureaucracy

A small employer does not need elaborate paperwork to handle this paragraph well. Name who is responsible for cleaning supplies and the drying and storage area, and put that in your written respiratory protection program, which already needs a program administrator under paragraph (c). Cover cleaning, storage, and the pre-use inspection in the training required by paragraph (k), including a demonstration, because workers who have never been shown how to wash a half-mask will not guess. And look at the setup itself. If the only place to wash and dry a respirator is a utility sink full of grease, the program will fail no matter how well it is written.

Keep this distinct from the neighboring duties as well. Cartridge change schedules belong to a different paragraph of the standard and depend on the contaminant and the conditions of use. Maintenance is also separate from the program evaluation in paragraph (l), where you ask whether the program is working. Treat paragraph (h) as the daily housekeeping that makes those other pieces mean something. A perfect fit test performed on a respirator that is later stored badly, left uncleaned, and never inspected tells you very little about the protection that worker has on the day the dust is heaviest.

This post is general information, not legal advice, and it does not guarantee that following it will make your program compliant. Read paragraph (h) and Appendix B-2 on OSHA's website, and check the manufacturer's instructions for each model you buy.

Related reading: Respiratory Protection Program Basics | Respirator Medical Evaluation | Voluntary Respirator Use

OSHA standards cited

Always verify current OSHA standards at osha.gov. This article reflects standards in effect at the date of publication.

Not sure where you stand?

Take the 5-minute compliance assessment. Answer a few questions about your business and get a prioritized list of what OSHA expects, free.

Start free assessment