Skip to main content
Equipment SafetyReviewed against current OSHA standards

What Goes on an Aerial Lift Pre-Start Inspection? A Free Checklist From The Lift Bros, Item by Item

A free aerial lift pre-start inspection checklist from The Lift Bros, item by item, and the OSHA rule behind it: 1926.453 for booms, 1926.451 for scissors.

Updated November 20, 2026
7 min read
By the WorkSafely safety team

Every scissor lift and boom lift that leaves the ground on your job should have been walked around first, before the shift, by someone who knows what a bad hose or a soft patch of ground looks like. This post answers the practical question of what that walkaround actually covers, item by item, and what you do when the lift fails it. If you want the wider picture first, our post on what OSHA requires before workers go up covers training, fall protection, and the rest of the aerial lift rules.

The walkaround below is built around a free checklist from The Lift Bros, a shop in Chouteau, Oklahoma that sells, repairs, and refurbishes scissor, boom, and mast lifts. They reached out after noticing our free OSHA checklists covered ladders, fall protection, and forklifts but had nothing for aerial lifts. That was a fair catch, and their sheet is a good one: it follows OSHA's own pre-start inspection list item for item, and it is free to print and share with your crew with no sign-up.

Which OSHA rule asks for the check depends on which lift you have

Small contractors often assume one rule covers anything with a platform. It does not, and the difference decides what you are actually required to do.

Boom lifts — extensible and articulating boom platforms — fall under 29 CFR 1926.453, OSHA's aerial lift standard for construction. Paragraph (b)(2)(i) is short and specific: lift controls "shall be tested each day prior to use to determine that such controls are in safe working condition."

Scissor lifts are not aerial lifts under that standard. OSHA said so directly in a 2000 letter of interpretation: scissor lifts meet the definition of a scaffold, so they are governed by the general scaffold rules in 1926.451 and the mobile scaffold rules in 1926.452(w). That brings in 1926.451(f)(3), which requires scaffolds to be "inspected for visible defects by a competent person before each work shift." A competent person, under 1926.32(f), is someone capable of identifying the hazards and authorized to take prompt corrective measures to eliminate them. In other words, not whoever happens to be standing nearest the machine.

Over both sits OSHA's Aerial Lifts fact sheet, which calls for a pre-start inspection before each work shift, following the manufacturer's recommendations. It breaks that inspection into vehicle components, lift components, and the work zone. The Lift Bros checklist uses exactly those three groups, which is why it works for both kinds of machine.

Part one: the machine on the ground

The first seven items on The Lift Bros sheet are the vehicle itself, checked with the platform stowed and nobody aboard. Fluid levels come first — oil, hydraulic, fuel, and coolant, whichever the machine actually has — followed by a look underneath for leaks. A fresh drip under a hydraulic lift is not a cosmetic problem; it is the system that holds the platform up telling you something.

Then wheels and tires, the battery and charger on electric units, the lower-level controls, the horn, gauges, lights, and backup alarm, and finally steering and brakes. None of these takes long, and none needs a mechanic. What they need is someone who actually looks rather than signs the sheet from the cab.

The lower controls deserve a moment of their own. They are how someone on the ground brings the platform down if the operator above cannot, so a ground control that sticks or does not respond is a reason to stop, not a note for later.

Part two: the parts that hold you up

The ten lift-component items are where a pre-start inspection earns its keep. The sheet starts with the operating and emergency controls — test them from the ground first, then from the platform, and make sure the operator knows where emergency lowering is before they need it.

From there it moves through the hydraulic, air, pneumatic, fuel, and electrical systems; the insulating components on insulated units; and the placards, warnings, and markings, including the load-capacity plate. A missing or unreadable capacity plate matters more than it looks. Under 1926.453(b)(2)(vi), boom and basket load limits specified by the manufacturer may not be exceeded, and nobody can stay inside a limit they cannot read.

The rest is structural: mechanical fasteners and locking pins, cables and wiring harnesses, outriggers and stabilizers on machines that have them, loose or missing parts, and the guardrail system. On a scissor lift, guardrails are the fall protection — an OSHA interpretation states that tying off is not required where protection is afforded by guardrails — so a missing chain or a gate that will not latch is a fall hazard, not a housekeeping item. On a boom lift, 1926.453(b)(2)(v) requires a lanyard attached to the boom or basket, so check that the fall protection is actually on board before the platform rises.

Part three: the ground and the air around it

The last nine items are the work zone, and they are the ones crews skip most often because the machine looked fine yesterday and the ground did not move overnight. Except sometimes it did.

Walk the path the lift will travel and the area it will work from. Look for drop-offs, holes, and unstable surfaces such as loose dirt; slopes, ditches, and bumps; debris and floor obstructions; and ceiling heights that will not clear the platform at full extension. Then look up: overhead power lines and communication cables, and other overhead obstructions such as beams, pipes, and door headers. Check for hazardous locations or atmospheres, for high wind and severe weather including ice, and for other people working close enough to be struck or to wander under the platform.

Ground conditions change with weather, with other trades, and with every move of the machine across a site. A work zone check done at the start of the shift is the minimum; the fact sheet expects hazards to be watched for during operation, too.

When something fails: tag it out, and mean it

A checklist only matters if a failed item stops the machine. OSHA's fact sheet is direct about this: defective aerial lifts come out of service, tagged out, until they are repaired. For scissor lifts, 1926.451(f)(4) says the same thing in scaffold terms — any part damaged or weakened below the required strength must be repaired, replaced, braced, or removed from service until it is.

In practice, that means a tag on the controls that names the defect, the keys pulled or the controls locked so the next crew does not take it out anyway, and a record of who repaired it before the tag comes off. The pressure to "just finish this one task" is exactly what the tag exists to resist.

If the lift is a rental, the yard's inspection when it left their lot is not your pre-start inspection. You are the employer of the person going up, and the check before each shift is yours. Our post on what OSHA expects when equipment isn't yours goes into the handoff in more detail.

The checklist is the floor, the operator's manual is the ceiling

The Lift Bros make this point on their sheet and it is worth repeating: the manufacturer's operator manual for the specific make and model takes precedence. OSHA's list is common to every machine. Your manual knows about the tilt alarm, the pothole guards, and the platform extension on that particular lift. Use the checklist to make sure nothing on the common list is missed, and use the manual for everything particular to the machine in front of you.

1926.453 does not prescribe a form, but a signed sheet with the date, the machine, and the hour meter is the simplest proof the check happened. It also shows the next operator what was found and what was fixed.

Get the checklists

The Lift Bros' free printable aerial lift pre-start inspection checklist covers all three groups, with OK, Fix, and Notes columns and space for the date, make and model, serial number, hour meter, and the inspector's signature. They also publish a longer guide to the daily aerial lift walkaround that is worth reading before you train a new operator.

We have added a WorkSafely version to our library too. The Aerial Lift Pre-Start Inspection checklist follows the same three OSHA groups, adds a tag-out step and a defect log, and cites the boom and scissor lift rules above. It is the newest entry in our free OSHA checklists and safety templates. Thanks to Braden and the team at The Lift Bros for pointing out the gap.

None of this makes a site compliant on its own. What it does is make the walkaround consistent: the same items, checked the same way, by someone who knows what to look for, before every shift.

Related reading: Aerial Lifts and Scissor Lifts: What OSHA Requires Before Your Workers Go Up | MEWP Safety: Keeping Mobile Elevating Work Platforms Compliant | You Rented the Lift, Not the Liability

OSHA standards cited

Always verify current OSHA standards at osha.gov. This article reflects standards in effect at the date of publication.

Not sure where you stand?

Take the 5-minute compliance assessment. Answer a few questions about your business and get a prioritized list of what OSHA expects, free.

Start free assessment