There is a floor jack in almost every small shop that nobody has ever thought of as equipment. It lives under a bench, it gets rolled out when a trailer needs a wheel off or a machine needs shimming, and it goes back under the bench when the job is done. Nobody remembers buying it. The capacity sticker wore off years ago. It has started to sink slowly under load, and the person who uses it most has learned to pump it once more every few minutes.

That jack is covered by a federal standard most shop owners have never read. This post answers a narrow question: what does 29 CFR 1910.244(a) actually require of the jacks in a general industry workplace, and what would it take to show that you meet it. If your concern is the vehicle lifts in an auto repair bay, which have no dedicated OSHA standard at all, our post on vehicle lift safety in auto repair shops covers that separate problem. This one is about the portable jacks that sit beside the lifts, and in every other kind of shop that has no lift.

Where the jack rule lives and what it covers

Section 1910.244 is titled "Other portable tools and equipment" and sits in Subpart P, the hand and portable powered tools subpart of the general industry standards. Paragraph (a) is headed simply "Jacks". It does not distinguish between hydraulic floor jacks, bottle jacks, screw jacks or ratchet jacks, so the sensible reading is that every jack you use to raise a load is in scope. The one place it singles out a type is the antifreeze rule for hydraulic jacks, discussed below.

It is a short rule, and that is part of why it gets ignored. There is no written program, no training curriculum, no certification form, just a handful of plain obligations about marking, operating and maintaining the jack. What turns common sense into an obligation is the inspection schedule, which is specific, and the tagging rule, which requires you to act when a jack fails.

If your work is construction rather than general industry, jacks fall under a separate rule in the construction standards, 1926.305. The obligations overlap, but check that standard directly rather than assuming this post maps onto it.

Rated load: the sticker that has to survive

Paragraph (a)(1) has two parts. The first puts the duty on the person using the jack: the operator must make sure the jack has a rating sufficient to lift and sustain the load. The second requires that the rated load be legibly and permanently marked in a prominent location on the jack, by casting, stamping or another suitable means.

The word that matters is permanently. A paper label that peels off after a year of hydraulic fluid and floor grime was arguably fine on the day the jack was bought and is not fine now. Many jacks carry their rating cast into the body or stamped on the saddle arm, and those meet the requirement for the life of the jack. Cheaper jacks often rely on a decal. When the decal is gone, the operator has no way to do what (a)(1) asks, because there is no longer a rating to check the load against.

The practical fix is unglamorous. Look at every jack you own. If the rating is cast or stamped, you are done. If it is a fading decal, find the rating from the manufacturer or model number and mark it permanently, with a metal stamp or an engraved tag fixed to the body. If you cannot establish what the jack is rated for, it should not be lifting anything. And if the weight of the load is unknown, as with a machine base nobody has weighed, find out before the jack goes under it.

Lifting and holding: base, cap, stop and cribbing

Paragraph (a)(2) is headed "Operation and maintenance", and its first three provisions describe how a jack is used.

The first deals with what is under and on top of the jack. If there is no firm foundation, the base of the jack must be blocked. If there is a possibility of the metal cap slipping, a block must be placed between the cap and the load. A jack on asphalt on a hot afternoon, on gravel, or on a cracked slab is not on a firm foundation, and the rule expects you to give it one. A jack whose saddle sits against a smooth, rounded or painted surface is the slipping case, and the wood block between cap and load is the rule's answer.

The second provision says the operator must watch the stop indicator, which must be kept clean, to determine the limit of travel, and that the indicated limit must not be overrun. A stop indicator caked in grime cannot be watched, which is why the rule bothers to say it must be kept clean.

The third provision is the one that matters most to anyone who ever gets under a load. After the load has been raised, it must be cribbed, blocked or otherwise secured at once. A jack is a lifting device, not a holding device. Hydraulic jacks bleed down, seals let go, and a load that has been sitting on a jack for twenty minutes is resting on a seal nobody has looked at in years. The rule does not say crib the load if someone is going under it, or crib it if the job will take a while. It says at once. Jack stands rated for the load, cribbing blocks, or the equipment's own supports all count as securing it. Leaving it on the jack does not.

This is the provision most worth turning into a shop rule anyone can repeat: the jack lifts, something else holds.

The six-month inspection nobody schedules

The maintenance provisions in (a)(2) are where the rule becomes specific. Hydraulic jacks exposed to freezing temperatures must be supplied with an adequate antifreeze liquid, which matters for any shop that keeps a jack in an unheated building, a service truck or an outdoor storage container through the winter. All jacks must be properly lubricated at regular intervals.

Then comes the inspection schedule. Each jack must be thoroughly inspected at times that depend on the service conditions, and the rule sets floors that those times may not go below. For a jack in constant or intermittent use at one location, the inspection must happen at least once every six months. For a jack sent out of the shop for special work, it must be inspected when it is sent out and again when it comes back. For a jack subjected to an abnormal load or shock, it must be inspected immediately before and immediately after.

Each trigger fits a familiar situation. The six-month floor covers the jack under the bench. The sent-out trigger covers the jack that rides in the service truck to a customer's site. The abnormal load trigger covers the jack that was under the trailer when it shifted. That last one is most often missed, because the moment of abnormal load is usually a moment when everyone is relieved nothing worse happened, and nobody thinks to look at the jack.

The rule does not prescribe what a thorough inspection consists of, so the manufacturer's instructions are the place to start. In practice, a thorough inspection looks at the things that fail: leaks around the ram and the release valve, a load that creeps down when the jack is held under weight, bent or cracked saddles and lifting arms, worn or seized wheels and casters on floor jacks, damaged handles and handle sockets, a stop indicator that cannot be seen, and a rated load marking that can no longer be read. The sentence in the rule that is easiest to overlook is the one that follows: repair or replacement parts must be examined for possible defects. A seal kit from an unknown supplier is a part like any other.

Nothing in 1910.244 explicitly requires you to write the inspection down. But an inspection that leaves no trace is an inspection you cannot show anyone, including yourself six months later when you are trying to remember whether it happened. A date and initials on a tag tied to the jack, or a line in whatever maintenance log the shop already keeps, is enough to turn a memory into a record.

Out-of-order jacks: the tag and the bench

The last provision in (a)(2) is the shortest. Jacks that are out of order must be tagged accordingly and must not be used until repairs are made.

The failure this is aimed at is familiar. A jack starts to leak. Everyone knows it leaks. It goes back under the bench with the others, and three weeks later a new hire, or a customer's employee, or the owner in a hurry, pulls it out and uses it. A tag on the handle reading "Do not use, leaks under load" with a date breaks that chain. Better still, the tagged jack goes somewhere that is not where the working jacks live, until it is repaired or thrown away.

Making it a habit in a shop with no safety staff

None of this requires a safety department. It requires knowing how many jacks you have, and that is the step most shops skip. Count them, including the ones in vehicles and the one that lives at the other building. Give each a simple identifier, even a paint mark or a numbered tag, and note its rated load and how the rating is marked. Put a recurring six-month reminder on the calendar you already use. Decide who inspects, and make that person the one who also checks a jack when it comes back from a customer's site or after anything unusual happens to it.

Then make cribbing visible. Keep jack stands and blocks next to the jacks, not in the back of a storage container, so that the right thing is also the easy thing.

Following this will not by itself make your shop compliant with every standard that touches lifting, and it is not a substitute for the manufacturer's instructions or the construction rules if your crews work on jobsites. What it does is close the gap between owning a jack and being able to say when it was last looked at, by whom, and what happens when it fails.

Related reading: The Vehicle Lift in Your Bay Has No OSHA Standard | The Tools in Every Shop: What OSHA 1910.242 Expects | OSHA's Safety Sign Standard: What 1910.145 Actually Requires

OSHA standards cited

Always verify current OSHA standards at osha.gov. This article reflects standards in effect at the date of publication.

Not sure where you stand?

Take the 5-minute compliance assessment. Answer a few questions about your business and get a prioritized list of what OSHA expects, free.

Start free assessment