The Door That Looks Like a Way Out: What OSHA 1910.37(b) Requires of Exit Signs and 'Not an Exit' Marking
29 CFR 1910.37(b) sets rules for exit signs, directional signs and 'Not an Exit' marking. What a small business has to post, light and keep clear at each door.
Stand in the back of your shop and imagine the lights have just gone out and someone is shouting about smoke. You know where the exit is, because you walk past it every day. The temp who started Monday does not. What they see is a row of doors: one to the parking lot, one to a storage closet, one to the restroom, one to a mezzanine stair that ends at a locked roof hatch. Which of those doors is the way out is a question the walls of your building are supposed to answer, and 29 CFR 1910.37(b) is the paragraph that says how.
This post is about that one question: what OSHA requires you to post, light and keep clear so that an exit can be told apart from every other door. It is narrower than a full egress review. If you want the wider walk-through of exit routes and emergency lighting, our post on emergency lighting and exit routes covers it, and the plan that tells people what to do once they reach the door belongs to your emergency action plan under 1910.38.
What 1910.37(b) actually says
The paragraph opens with a general rule: lighting and marking must be adequate and appropriate. It then breaks that into seven specific requirements, and most of them are easier to meet than people expect, which is exactly why they are easy to let slide.
Under 1910.37(b)(1), each exit route must be lighted well enough that an employee with normal vision can see along it. Under (b)(2), each exit must be clearly visible and marked by a sign reading "Exit." Under (b)(3), each exit route door must be free of decorations or signs that obscure its visibility. Under (b)(4), where the direction of travel to the exit or the exit discharge is not immediately apparent, signs must be posted along the exit access indicating the direction to the nearest exit, and the line of sight to an exit sign must be clearly visible at all times. Under (b)(5), each doorway or passage along an exit access that could be mistaken for an exit must be marked "Not an Exit" or with a similar designation, or be identified by a sign indicating its actual use, such as "Closet." Under (b)(6), each exit sign must be illuminated to a surface value of at least five foot-candles by a reliable light source and be distinctive in color, with self-luminous or electroluminescent signs allowed where they have a minimum luminance surface value of at least 0.06 footlamberts. And under (b)(7), the word "Exit" must be in plainly legible letters at least six inches high, with the principal strokes of the letters at least three-fourths of an inch wide.
That is the whole of it. Notice what is in there and what is not. The rule cares about whether a person can find the exit and tell it apart from a dead end. It does not specify a brand of sign, and it does not ask you to buy anything elaborate. It asks you to make the right door obvious and the wrong doors honest.
The doors that are not exits
The most commonly forgotten part of the paragraph is (b)(5), because it is about doors you do not think of as part of your emergency plan at all.
In a small building, the doors that could be mistaken for an exit are usually the ones that look like the real one: the same metal door with the same push bar, leading to a utility room. A door at the end of a corridor that people instinctively run toward, which turns out to open onto a stairwell down to a basement with no outside access. A side door that used to be an exit before the landlord fenced in the yard behind it. A door painted the same color as the exit door three feet away.
The test the standard uses is whether the doorway "could be mistaken for an exit." That is a judgement made from the point of view of someone who does not know the building, in poor visibility, in a hurry. If you are unsure, ask someone who has never been inside to walk from the back of the floor to the outside and watch which doors they reach for. Any door they hesitate at is a candidate for marking.
You have a choice in how you mark it. "Not an Exit" is the familiar sign, but the standard equally accepts a sign naming the room's actual use. For a storage closet, "Storage" or "Closet" is often clearer to a stranger than a negative, and it tells them something true about the building rather than only what to avoid. What you cannot do is leave the door bare and rely on people knowing.
Seeing the sign from where people actually stand
Paragraph (b)(4) is where most small floor plans run into trouble, because of how buildings change after the signs go up.
The rule is that where the way to the exit is not immediately apparent, directional signs must be posted, and an exit sign must be visible in the line of sight at all times. "Immediately apparent" depends on the layout. In a single open room with the exit door on one wall, the exit sign over the door may be all you need. Once there are partitions, racking, offices, or a turn in the route, someone standing in the far corner may not be able to see the exit sign at all. That is where a directional sign, with an arrow toward the nearest exit, has to go.
The common failure is not that the signs were never posted. It is that the building filled in around them. A row of pallet racking goes up and blocks the view of the exit sign from half the warehouse. A new office is framed in and the corridor now turns. A display or a stack of inventory is set down where a directional sign used to be visible. None of these changes was made with egress in mind, and each one can quietly put part of your floor out of the line of sight of every exit sign.
Paragraph (b)(3) is a close cousin. Holiday decorations, posters, a whiteboard, a coat rack or a curtain hung across a door can all obscure an exit route door. The standard does not ban decorations; it bans the ones that hide the door. It is worth checking each exit door specifically after anything seasonal goes up or comes down.
Lit, legible and distinctive
Paragraphs (b)(6) and (b)(7) are the physical specifications, and they are where the sign itself either passes or fails.
The illumination requirement is about the light falling on, or coming from, the sign. An externally lit sign needs at least five foot-candles on its surface from a reliable light source. An internally lit or self-luminous sign needs to meet the luminance value in the standard. In practice, most small businesses use a manufactured, internally lit exit sign, and the questions to ask are simple ones: is it actually lit right now, and does it stay lit if the power to that circuit drops? A sign with a dead bulb or an exhausted battery is still a sign on the wall, but it is not illuminated, and the moments when people most need to see it are the moments when the building lighting may be failing too.
The legibility requirement, six-inch letters with three-quarter-inch strokes, is usually met by any commercial exit sign. It is most likely to be missed by improvised ones: a printed sheet of paper taped to a door, a hand-lettered sign, or a small decal. If you find a paper "EXIT" sign anywhere in your building, it was probably put there in good faith to fill a gap, and it is a sign that the gap needs a proper fix.
"Distinctive in color" does not name a specific color in the federal standard. What it rules out is an exit sign that blends into the wall, or one that looks like every other sign around it. Your local building and fire codes may say more about sign color and emergency power than OSHA does, and they apply alongside the federal rule, so it is worth knowing what your local fire marshal expects.
Making it part of a routine, not a project
None of 1910.37(b) is difficult in isolation. The reason it slips is that it is the kind of thing that was right when the building was set up and then drifted, one rack, one decoration and one dead battery at a time. The practical fix is to look at it on a schedule rather than waiting for an inspection or a fire drill to reveal it.
A short walk on a regular basis, done from the point of view of a newcomer, catches most of it. Start at the furthest point from each exit and walk toward it, checking that you can see an exit sign or a directional sign the whole way. At each door along the route, ask whether a stranger could mistake it for the way out, and if so, whether it is marked. At each exit, check that the sign is lit, readable and not covered. Test any battery-backed signs according to their manufacturer's instructions. Write down what you checked and what you fixed, with a date, so that the next walk starts from a record rather than from memory.
It also helps to make egress part of the conversation whenever the floor changes. When racking is moved, a wall is added, or a room changes use, ask one extra question: can everyone on this floor still see the way out, and is every new door that might look like an exit marked as what it really is?
Following these steps will not by itself make your building compliant; your layout, your local codes and the rest of Subpart E all matter. What it does is close the most ordinary gap in egress, the one where the exit exists but a frightened stranger cannot find it.
Related reading: Emergency Lighting and Exit Routes | Emergency Action Plans Under 1910.38 | Safety Signs and Tags Under 1910.145
OSHA standards cited
- 29 CFR 1910.37
General Industry Standards
- 29 CFR 1910.38
General Industry Standards
- 29 CFR 1910.145
General Industry Standards
Always verify current OSHA standards at osha.gov. This article reflects standards in effect at the date of publication.
Not sure where you stand?
Take the 5-minute compliance assessment. Answer a few questions about your business and get a prioritized list of what OSHA expects, free.
Related Articles
Continue learning about OSHA compliance and workplace safety
Emergency Planning
The Doors Open at Six on Black Friday: What OSHA's Exit Route Rules Ask of a Small Store's Crowd Plan
Black Friday crowds meet 29 CFR 1910.36 and 1910.37 at the door. What OSHA's exit route rules and crowd guidance mean for a small retailer's opening plan.
Emergency Planning
The Alarm Nobody Ever Tested: What OSHA 1910.165 Actually Requires
OSHA 1910.165 governs how your crew learns to evacuate. Learn the two-month testing rule, the ambient noise standard, and the small-employer exception.
Emergency Planning
Who Needs an Emergency Action Plan, and What 1910.38 Requires It to Contain
Which employers 1910.38 applies to, when an oral plan is allowed instead of a written one, and the six elements the standard says every emergency action plan must contain.