Stairs in Your Shop or Warehouse: What OSHA 1910.25 Asks You to Measure
OSHA 1910.25 covers general industry stairs: riser and tread uniformity, headroom, handrails and stair rails. A walk-through for small shop owners.
Think about the staircase in your building that nobody ever thinks about. It might be the steel stairs up to the office loft, the wooden steps someone built to get over a raised floor at the back of the shop, or the stairs down to a basement storage room. People climb them with a box in their hands, in a hurry, sometimes in poor light. They have been there for years, and the only time anyone looks at them is after somebody slips.
OSHA does have a rule for those stairs, and it is more specific than most owners expect. Section 1910.25 of the walking-working surfaces standard covers stairways in general industry, and it is a short list of things you can check with a tape measure and a few minutes. This post walks through what it asks for and where small employers most often fall short. It is general information, not legal advice, and you should read the current text of the standard on osha.gov alongside it.
What counts as a stairway under the rule
The standard applies to stairs that employees use, including fixed industrial stairs, stairs built into mezzanines and platforms, and the stairs at a loading area or equipment access point. It sits alongside 1910.23, which covers ladders, and 1910.28 and 1910.29, which deal with when fall protection is needed and what guardrail systems must look like. If you have already read our piece on mezzanine guardrails and toeboards, the open side of a staircase follows similar logic, and the stair rail that protects it is built to the same family of criteria.
One practical point: the stairs do not have to be new for the rule to apply. OSHA's revision of Subpart D gave existing installations some flexibility on certain construction details, but the condition and use of the stairs, including keeping them in safe condition, is your responsibility every day. If you are not sure whether an older staircase is covered by an exception, treat that as a question to resolve rather than an assumption to make.
Uniform steps are the hidden hazard
The most common stair injury is not a dramatic fall from the top. It is a misstep on a stair that was a little different from the ones around it. Our bodies learn a staircase after two or three treads and then stop watching our feet. If one riser is taller or one tread is shallower, the rhythm breaks and the foot lands wrong.
For that reason 1910.25 sets limits on how much the riser height and tread depth can vary within a flight. The standard allows only a small variation between the largest and smallest riser, and the same for treads, measured in fractions of an inch. It also sets an upper limit on riser height and a lower limit on tread depth, roughly in the neighborhood of nine and a half inches for each on standard stairs. The angle of the staircase has to fall within a defined range from the horizontal as well.
You do not need to memorize the numbers to act on this. Measure the first step, the last step, and a couple in between with a tape and write down what you find. A tread that has been resurfaced, a floor that was raised with new epoxy or plywood at the bottom landing, or a top step that was cut down to clear a door can all create a step that no longer matches. Those changes are easy to make and easy to forget about.
Headroom and width
Two other dimensions come up in practice. The standard calls for clear vertical space above the treads so a person carrying something does not strike a duct, a sprinkler pipe or a low beam. That figure is in the range of six feet eight inches, measured from the leading edge of the tread. Staircases in older buildings and in retrofitted spaces are where this gets violated, because someone ran new conduit or ventilation across the stairwell years after the stairs were built.
Width is the other. The standard sets a minimum clear width between the barriers on either side of the stairs, measured in inches. A staircase that has become a storage shelf, with boxes lining one side or a cart parked against the wall, effectively shrinks that width and also blocks the path people need in an emergency. Because stairs are usually part of the exit route as well, our piece on emergency lighting and exit routes is worth a look if your stairs are on the way out of the building.
Handrails and stair rails are not the same thing
Owners sometimes use the words interchangeably, but 1910.25 treats them as two separate things. A handrail is what you grip as you climb. A stair rail is the barrier along an open side that keeps you from going over the edge. The standard expects stairs that rise a certain amount, four or more risers or more than thirty inches, whichever is less, to have a handrail, and it expects a stair rail along any open side or edge.
The detail work then moves to 1910.29. A handrail should sit within a height range measured from the front edge of the tread, and the standard sets a minimum clearance between the handrail and anything behind it so a hand can wrap around it. It also needs to be smooth enough that a hand sliding along it does not catch on a protruding bolt or a splintered edge. The stair rail on the open side has to meet the same height criteria as a guardrail, with the top edge at about forty-two inches, give or take three, and be strong enough to take a meaningful load without giving way. Check that no one has bolted a hook, a sign or a conduit clamp onto the top of the handrail that interferes with a sliding grip.
A rail that wobbles is a failed rail. Grab it and push firmly in the direction a falling person would. If it flexes, rattles in its brackets, or pulls away from the wall, it is not doing the job even if it is the correct height. Wall brackets loosen over time, especially on stairs that carry heavy foot traffic and on rails that people use to haul themselves up while holding a load in the other hand.
Surfaces, light and housekeeping
The standard also expects stair treads to have a slip-resistant surface, and for good reason. Metal treads collect oil and water. Wooden ones wear smooth. Painted concrete steps turn slick in winter when slush is carried in on boots. Look at whether the nosing has worn through or whether grit tape has peeled away, and consider how the staircase behaves when it is wet, because that is when it matters.
Lighting is not spelled out in 1910.25 itself, but it is hard to separate from the stairs. A staircase in shadow makes every other defect harder to see. A burned-out fixture over a landing is a maintenance item that turns into an injury if it sits long enough. And housekeeping rules under 1910.22 still apply: stairs are not a place to leave boxes, hoses, or extension cords, even briefly.
A simple routine that keeps stairs honest
For a small business the practical approach is a quick periodic walk, not a project. Choose someone, perhaps the person who already does your fire extinguisher checks, and give them a short list to carry. Do the risers and treads look even? Is there clear headroom the whole way? Is a handrail present and solid on the side people use? Is the open side protected? Are the treads gripping, clean and clear of stored items? Write down the date and any fixes made, so a pattern shows up over time.
When something fails, fix it or take the stairs out of service until you can, and make sure employees know which route to use in the meantime. If you are making changes, such as adding a platform, moving a door or building new access to a loft, bring the stairs into the plan from the start. It is much cheaper to build a stair to the standard than to rebuild one afterward.
The bottom line
Stairs look simple, which is why they are neglected. The requirements in 1910.25, supported by the rail criteria in 1910.29, are built around a handful of measurements and conditions that anyone can check: even steps, enough headroom, a usable handrail, a protected open side, and a surface that grips. A thirty-minute walk with a tape measure will tell you most of what you need to know. Following a post like this one does not make a workplace compliant, and your specific stairs, building and state rules may add requirements, so confirm details against the standard itself or with a qualified professional.
Related reading: Struck-By Hazards: The Workplace Killer Most Small Businesses Underestimate | Secondary Container Labeling: The GHS Compliance Gap Most Small Businesses Miss | OSHA's Safety Sign Standard: What 1910.145 Actually Requires
OSHA standards cited
- 29 CFR 1910.25
General Industry Standards
- 29 CFR 1910.23
General Industry Standards
- 29 CFR 1910.28
General Industry Standards
- 29 CFR 1910.29
General Industry Standards
- 29 CFR 1910.22
General Industry Standards
- 29 CFR 1910.145
General Industry Standards
Always verify current OSHA standards at osha.gov. This article reflects standards in effect at the date of publication.
Not sure where you stand?
Take the 5-minute compliance assessment. Answer a few questions about your business and get a prioritized list of what OSHA expects, free.
Related Articles
Continue learning about OSHA compliance and workplace safety
Hazard Control
Snow and Ice Are Written Into the Rule: What OSHA 1910.22(a)(3) Asks of Your Dock, Doorways and Walkways on a Frozen Morning
OSHA 1910.22(a)(3) names snow and ice as hazards walking-working surfaces must be kept free of. What that means for small shops on the first frozen morning.
Hazard Control
Red Cans and Yellow Stripes: What OSHA's Safety Color Code Actually Requires in a Small Shop
29 CFR 1910.144 sets red for flammable-liquid cans and danger signs and yellow for caution and physical hazards. Here is what it asks of a small shop.
Hazard Control
Mezzanine Guardrails and Toeboards: What OSHA 1910.29 Actually Measures
OSHA 1910.29 sets the height, strength and gap rules for guardrails and toeboards. What a small warehouse or shop owner needs to check on a mezzanine edge.