Skip to main content
Electrical SafetyReviewed against current OSHA standards

The Rubber Gloves in the Service Truck: What OSHA 1910.137 Requires Before an Electrician Puts Them On

OSHA 1910.137 sets daily inspection, air testing and periodic retesting for rubber insulating gloves. See what small electrical and HVAC shops must document.

Updated October 10, 2026
8 min read
By the WorkSafely safety team

Somewhere in the back of a service truck, behind the ladder and under a coil of wire, there is a canvas bag. Inside it is a pair of red rubber gloves with black leather protectors. The technician who owns the truck bought them when he started, wore them twice last year to swap a breaker in a panel that could not be shut off, and has not looked at them since. If you asked him whether they are still good, he would say yes, because they look fine.

That answer is the problem this post is about. Rubber insulating gloves are the one piece of protective equipment where "looks fine" tells you almost nothing. A pinhole you cannot see, a patch of cracking from ozone, or a glove that spent a summer baking on a dashboard can all look like new rubber and still fail at the exact moment a hand touches an energized part. OSHA's standard on electrical protective equipment, 29 CFR 1910.137, exists to turn that unreliable visual judgment into a routine with inspection, testing, storage and records. If your shop employs anyone who works near exposed energized parts, you own that routine.

When the standard comes into play

Section 1910.137 does not decide whether your people may work on energized equipment. Other rules do that. The general industry electrical work practices in Subpart S start from the position that live parts should be de-energized before an employee works on or near them, with narrow exceptions where shutting power off creates a greater hazard or is infeasible because of equipment design or operational limits. When a qualified person does work near exposed energized parts, 1910.335(a)(1) requires the employer to provide, and the employee to use, electrical protective equipment suited to the body part and the job. Insulating gloves are the most common answer to that sentence.

Once you hand someone a glove under that obligation, 1910.137 governs the glove. It covers two things: what the equipment must be (it has to meet the consensus standards the rule incorporates by reference, which is mostly the manufacturer's problem) and how the employer keeps it fit for use, which is entirely yours. The second part is where small shops fall behind, because it asks for habits rather than a purchase.

The same rule reaches blankets, line hose, covers and sleeves made of rubber. The glove is simply the item a one- or two-person electrical, HVAC or maintenance operation is most likely to own, so it makes the best example.

The inspection before each day's use

The first habit is the one that costs nothing. Section 1910.137(b)(2) requires rubber insulating equipment to be inspected for damage before each day's use and immediately after any incident that could reasonably be suspected of having caused damage. A glove that got caught on a sharp edge, dropped into a solvent, or squeezed under a toolbox lid has had an incident, whether or not anyone noticed.

For gloves, the standard adds an air test to the inspection. In practice that means rolling the cuff to trap air and squeezing the glove, then listening and feeling for leaks, and checking the whole surface including between the fingers. The rule also lists conditions that disqualify the equipment on sight: holes, tears, punctures or cuts; ozone cutting or checking, which looks like fine cracks along folds and stretched areas; an embedded foreign object; and texture changes such as swelling, softening, hardening, or becoming sticky or inelastic. Any other defect that could damage the insulating properties also takes the glove out of use. A glove with one of those defects does not get worn "just for this one job."

A practical point for owners: the person doing the inspection is the person who is about to rely on the glove, often alone, in a hurry, at a customer's site. The routine only holds if it is short and the tools are in the bag. Keep it simple, with a written one-paragraph procedure taped inside the glove bag and an expectation that the check happens before the truck leaves the lot or before the first panel is opened, not after.

Testing is not the same as inspecting

The part of 1910.137 that surprises small employers is the periodic electrical test. Rubber insulating equipment must be subjected to periodic electrical tests, with test voltages and maximum intervals set by the standard's tables. These are done by a laboratory or a shop with the right equipment, not by the technician in the field. The test voltage is applied to the glove to see whether it withstands it, which is the only way to learn what the insulation can actually do.

The intervals depend on the type of equipment. For rubber insulating gloves the maximum interval once the gloves are issued for service is six months. Blankets and sleeves have longer intervals, and covers and line hose are tested when their insulating value is in doubt. New equipment is tested before first issue, and the standard also limits how long tested but unissued equipment can sit on a shelf before it needs a fresh test. Read the current tables in the standard itself when you set your schedule, because the interval is the number an inspector will compare against your paperwork.

The calendar logic is where small shops slip. A pair of gloves bought two years ago and worn rarely has probably blown through four test dates. The six months runs whether the gloves were used or not, and the standard does not carve out an exception for "we hardly ever use them." If the gloves live in a truck and are used twice a year, the honest options are to put them on a six-month test calendar, or to decide your people will not do energized work and make that a written rule enforced by supervision.

Equipment that fails an inspection or an electrical test may not be used. The rule allows certain repairs to rubber equipment, such as vulcanizing patches in particular areas, but repaired equipment must be retested before an employee wears it. For gloves, most shops simply replace a failed pair, which is cheaper than arguing about a repair.

Certification and the paper trail

Section 1910.137(b)(2) also requires the employer to certify that the equipment has been tested as the standard requires. The certification must identify the equipment that passed and the date it was tested. A test lab will normally mark the glove and send a report; your job is to keep that paperwork where you can find it and tie it to the specific pair.

That last clause matters more than it sounds. If three technicians each have a pair of identical gloves, a certification that says "gloves, passed" proves nothing. Give each pair an identifier, write it on the glove bag and in your log, and record the test date and the next due date. A simple spreadsheet or a binder page is enough. When an inspector asks to see the test records for the gloves in the truck, you want to hand over a page where the identifier on the paper matches the identifier on the glove, and the date is inside the interval.

Storage, cleaning and the leather protectors

Insulating rubber is damaged by what happens to it between jobs. The standard requires the equipment to be cleaned as needed to remove foreign substances, and to be stored where light, temperature extremes, excessive humidity, ozone and other injurious substances will not reach it. A glove stuffed in a toolbox with a can of solvent, a hot dashboard, or a bin next to an electric motor that produces ozone is aging faster than the calendar suggests.

The usual guidance, which tracks the manufacturers' instructions, is to store gloves in a bag or box made for them, laid flat or hung without folds, away from heat and chemicals. Do not store them rolled tight or folded at the cuff. Do not write on them with a marker unless the manufacturer allows it, because some inks affect rubber.

Leather protectors also matter. The rubber glove gives the insulation, but it is thin and easily cut, so protector gloves are worn over it, with narrow exceptions. A protector worn over a damaged rubber glove hides the damage and gives a false sense of safety, which is another reason the pre-use inspection is done on the rubber with the protector off.

What a small shop should have in place

Putting this together does not require a safety department. It requires a decision and a short list of owned tasks. Decide first whether your employees will ever work on or near energized parts that cannot be shut off. If the answer is no, write that down as a policy, train on it under the electrical safety-related work practices training requirements in 1910.332, and keep insulating gloves out of the trucks so nobody is tempted to improvise. If the answer is yes, then each pair of gloves needs an identifier, a pre-use inspection habit that includes the air test, a laboratory test every six months, records that match the glove, and storage that protects the rubber.

Notice what the standard does not do. It does not make a glove a substitute for training or for planning the job. Your people need to be qualified for the work, the correct class of glove has to match the voltage involved, and the use voltage limits in the standard's tables apply. If you are unsure which class a task needs, that is the moment to stop and ask a qualified electrical safety professional, not to guess.

This post describes the general shape of 29 CFR 1910.137. It is not legal advice and following it does not guarantee compliance, so read the standard and your state plan's version if you operate in a state that runs its own program. The point to carry back to the shop is the one the technician in the first paragraph missed: a glove is only protective if someone has recently proven that it is. Pull the bag out of the truck this week, find the last test date, and see whether it is inside six months.

Related reading: The Frayed Cord in the Drawer: What OSHA's 1910.334 Actually Requires Before Every Shift | Portable Generators and Temporary Power: What OSHA Requires Before You Plug In | The Extension Cord Nobody Tested: What an Assured Equipment Grounding Conductor Program Requires on Small Construction Sites

OSHA standards cited

Always verify current OSHA standards at osha.gov. This article reflects standards in effect at the date of publication.

Not sure where you stand?

Take the 5-minute compliance assessment. Answer a few questions about your business and get a prioritized list of what OSHA expects, free.

Start free assessment